資源描述:
《GB3836.7-2004爆炸性氣體環(huán)境用電氣設(shè)備第7部分-充砂型q》由會(huì)員上傳分享,免費(fèi)在線閱讀,更多相關(guān)內(nèi)容在行業(yè)資料-天天文庫(kù)。
ICS29.260.20K35蕩黯中華人民共和國(guó)國(guó)家標(biāo)準(zhǔn)GB3836.7-2004/IEC60079-5:1997代替GB3836.7-1987爆炸性氣體環(huán)境用電氣設(shè)備第7部分:充砂型“ql}Electricalapparatusforexplosivegasatmosphere-Part7:Powerfilling"q"(IEC60079-5:1997,Electricalapparatusforexplosivegasatmospheres-Part5:Powderfilling"q",IDT)2004-05-14發(fā)布2005-02-01實(shí)施中華人民共和國(guó)國(guó)家質(zhì)量監(jiān)督檢驗(yàn)檢疫總局發(fā)布中國(guó)國(guó)家標(biāo)準(zhǔn)化管理委員會(huì)
1GB3836.7-2004/IEC60079-5:1997目次前言··················································································································??I1范圍···············································································································??12規(guī)范性引用文件··············································································....??,..?13術(shù)語(yǔ)和定義·····································································································??14結(jié)構(gòu)要求·······································································································??24.1外殼····························,····················,················································,·······??24.2填充材料········································································································一34.3距離············································································································??34.4材料的使用··································································································??44.5電纜引人裝置和絕緣套管·······························································.........??,,.??44.6能量貯存裝置·········································.......·..·····.·······............................??44.7溫度限制····································································································??44.8故障條件······································································································??45檢查和試驗(yàn)·················································,····················································??65.1型式檢查和試驗(yàn)···································,······,···························.....??,.·??65.2出廠檢查和試驗(yàn)·········································································..??,..??66標(biāo)志········,·······························································································,·??6圖填料的介電強(qiáng)度試驗(yàn)裝置表填料內(nèi)的距離···········??表2爬電距離和通過(guò)填料的距離
2GB3836.7-2004/IEC60079-5:1997前言GB3836的本部分的全部技術(shù)內(nèi)容為強(qiáng)制性。GB3836《爆炸性氣體環(huán)境用電氣設(shè)備》系列標(biāo)準(zhǔn)共分為若干部分,本部分是該系列標(biāo)準(zhǔn)的第7部分:—第1部分:通用要求;—第2部分:隔爆型“d’;—第3部分:增安型“e’;—第4部分:本質(zhì)安全型..i;—第5部分:正壓外殼型“P"}—第6部分:油浸型“o’;—第7部分:充砂型“q,’;—第8部分:無(wú)火花型“n’;—第9部分:澆封型“m,’;—第11部分:最大試驗(yàn)安全間隙測(cè)定方法;—第12部分:氣體或蒸氣混合物按照其最大試驗(yàn)安全間隙和最小點(diǎn)燃電流的分級(jí),—第13部分:爆炸性氣體環(huán)境用電氣設(shè)備的檢修;—第14部分:危險(xiǎn)場(chǎng)所分類;—第15部分:危險(xiǎn)場(chǎng)所電氣安裝(煤礦除外)。本部分等同采用IEC60079-5:1997(爆炸性氣體環(huán)境用電氣設(shè)備第5部分:充砂型.q"),并在編寫格式上符合GB/T1.1-2000的規(guī)定。本部分與GB3836.7-1987相比,主要差異如下:1)標(biāo)準(zhǔn)名稱由《爆炸性環(huán)境用防爆電氣設(shè)備充砂型電氣設(shè)備“9.I》改為《爆炸性氣體環(huán)境用電氣設(shè)備第7部分:充砂型、,’);2)電氣設(shè)備的適用條件修訂:原標(biāo)準(zhǔn)額定電壓不超過(guò)6kV,在使用時(shí)活動(dòng)部件不直接與填料接觸的電氣設(shè)備,才允許制成充砂型,而本部分規(guī)定額定電流小于(或等于)16A,額定功率損耗小于(或等于)1000VA,連接的輸人電壓不超過(guò)1000V;3)修改了術(shù)語(yǔ)和定義,增加了7條定義;4)增加了外殼防護(hù)等級(jí)為IP54或更高時(shí)應(yīng)該配置呼吸裝置的要求;5)增加了溫度限制保護(hù)裝置的要求;6)增加了故障條件;7)增加了材料的燃燒試驗(yàn)和填充材料的介電強(qiáng)度試驗(yàn)要求;8)增加了表1填料內(nèi)的距離;9)增加了表2爬電距離和通過(guò)填料的距離;10)增加了外殼封閉方法的要求;11)增加了圖1填料的介電強(qiáng)度試驗(yàn)裝置;12)刪除了最小安全高度;13)刪除了有機(jī)材料的使用要求;14)刪除了格網(wǎng)的使用要求;
3GB3836.7-2004/IEC60079-5:199715)刪除了電氣距離;16)刪除了充砂型原理圖;17)刪除了圖2試驗(yàn)裝置。本部分自實(shí)施之日起,代替GB3836.7-1987。凡不符合本部分規(guī)定的產(chǎn)品均應(yīng)在兩年內(nèi)過(guò)渡完畢。本部分由中國(guó)電器工業(yè)協(xié)會(huì)提出。本部分由全國(guó)防爆電氣設(shè)備標(biāo)準(zhǔn)化技術(shù)委員會(huì)歸口。本部分起草單位:南陽(yáng)防爆電氣研究所、煤科總院上海分院、天津化工研究院、沈陽(yáng)市中興防爆電器廠、浙江華榮防爆電器有限公司、國(guó)營(yíng)啟東防爆電器儀表廠。本部分主要起草人:李合德、宋榮敏、曹光輝、徐建文、肇桂林、何金田、龔玉偉、侯彥東。本部分1983年首次發(fā)布,2004年5月第一次修訂。本部分委托全國(guó)防爆電氣設(shè)備標(biāo)準(zhǔn)化技術(shù)委員會(huì)負(fù)責(zé)解釋。
4GB3836.7-2004/IEC60079-5:1997爆炸性氣體環(huán)境用電氣設(shè)備第7部分:充砂型“q;范圍GB3836的本部分規(guī)定了爆炸性氣體、蒸氣和薄霧環(huán)境用的充砂型電氣設(shè)備、電氣設(shè)備部件和Ex元件的結(jié)構(gòu)、試驗(yàn)及標(biāo)志的特殊要求注充砂型電氣設(shè)備及Ex元件包括:電子電路、傳感器、保護(hù)熔斷器、繼電器、本安電氣設(shè)備、關(guān)聯(lián)電氣設(shè)備、開(kāi)關(guān)等等。本部分是對(duì)GB3836.1適用于充砂型電氣設(shè)備要求的補(bǔ)充,本部分適用于符合下列條件的電氣設(shè)備、電氣設(shè)備部件及Ex元件:—額定電流小于(或等于)16A;—額定功率損耗小于(或等于)1000VA,連接到電源電壓不超過(guò)1000Ve規(guī)范性引用文件下列文件中的條款通過(guò)GB3836的本部分的引用而成為本部分的條款。凡是注明日期的引用文件,其隨后所有的修改單(不包括勘誤的內(nèi)容)或修訂版均不適用于本部分,然而,鼓勵(lì)根據(jù)本部分達(dá)成協(xié)議的各方研究是否可使用這些文件的最新版本。凡是未注日期的引用文件,其最新版本適用于本部分。GB3836.1-2000爆炸性氣體環(huán)境用電氣設(shè)備第1部分:通用要求(eqvIEC60079-0:1998)GB3836.2-2000爆炸性氣體環(huán)境用電氣設(shè)備第2部分:隔爆型"d"(eqvIEC60079-1;1990第1次修訂(1993))GB3836.3-2000爆炸性氣體環(huán)境用電氣設(shè)備第3部分:增安型"e"(eqvIEC60079-7:1990)GB3836.4-2000爆炸性氣體環(huán)境用電氣設(shè)備第4部分:本質(zhì)安全型"i"(eqvIEC60079-11;1999)GB4208-1993外殼防護(hù)等級(jí)(IP代碼)(eqvIEC60529:1989)GB9364.1-1997小型熔斷器第1部分:小型熔斷器定義和小型熔斷體通用要求(idtIEC60127-1:1988)GB13539.1-2002低壓熔斷器第1部分:基本要求(IEC60269-1:1998,IDT)ISO565-199。試驗(yàn)格網(wǎng)金屬絲網(wǎng),鉆孔的金屬盤和電鑄板孔徑的標(biāo)準(zhǔn)尺寸術(shù)語(yǔ)和定義對(duì)于GB3836的本部分來(lái)說(shuō),采用下列定義和GB3836.1的一些定義。3.1充砂型,"q"powderfilling"q"電氣設(shè)備的一種防爆型式,將能點(diǎn)燃爆炸性氣體的導(dǎo)電部件固定在適當(dāng)位置上,且完全埋入填充材料中,以防止點(diǎn)燃外部爆炸性氣體環(huán)境。注:這種防爆型式不能阻止爆炸性氣體進(jìn)人設(shè)備和Ex元件而被電路點(diǎn)燃。但是,由于填充材料中空隙小,且火焰通過(guò)填充材料中的通路時(shí)被熄滅,從而防止外部爆炸3.2填充材料fillingmaterial石英或玻璃顆粒。
5GB3836.7-2004八EC60079-5;19973.3外部最高電壓Umexternallyappliedmaximumvoltage"U."由制造廠規(guī)定的、能加在電氣設(shè)備連接件上且不影響充砂防爆型式的交流電壓的最高有效值或直流電壓最高值。3.41作電壓workingvoltage在電路開(kāi)路條件或正常運(yùn)行條件下,以額定電壓供電(不考慮瞬間值)時(shí),跨越任何絕緣可能出現(xiàn)的交流電壓的最高有效值或直流電壓最高值。3.5爬電距離creepagedistance兩個(gè)導(dǎo)電部分之間沿絕緣材料表面的最短距離。3.6班蓋層下的爬電距離creepagedistanceundercoating沿著覆蓋了絕緣層的絕緣介質(zhì)表面的兩導(dǎo)電部件之間的最短距離。3.7通過(guò)填料的電氣間隙distancethroughfillingmaterial兩導(dǎo)電部件間通過(guò)填充材料的最短距離。3.8熔斷器額定電流Ioinfuserating"Io"按GB9364.1或制造廠規(guī)定的熔斷器額定電流。結(jié)構(gòu)要求4.1外殼4.1.1機(jī)械強(qiáng)度由充砂型.}q”保護(hù)的電氣設(shè)備、設(shè)備部件及Ex元件應(yīng)符合GB3836.1中高機(jī)械危險(xiǎn)程度相對(duì)應(yīng)的沖擊能量的要求(見(jiàn)機(jī)械型式試驗(yàn)),并且應(yīng)符合本部分中5.1及5.2規(guī)定的壓力試驗(yàn)要求。安裝在符合GB3836.1要求的其他外殼內(nèi)的設(shè)備或Ex元件僅需符合本部分中5.1及5.2規(guī)定的壓力試驗(yàn)要求。如果不是Ex元件,這些設(shè)備應(yīng)按照GB3836.1標(biāo)志“X”符號(hào)。4.1.2外殼防護(hù)等級(jí)充砂型設(shè)備、充砂型設(shè)備部件或充砂型Ex元件在其正常運(yùn)行條件下,即在正常使用中其外殼的所有開(kāi)口都閉合情況下,至少應(yīng)符合GB4208規(guī)定的IP54防護(hù)等級(jí)。若防護(hù)等級(jí)是IP55或更高,則外殼應(yīng)配置呼吸裝置。具有呼吸裝置的外殼應(yīng)符合按GB4208規(guī)定的IP54防護(hù)等級(jí)。僅在清潔、干燥房間內(nèi)使用的充砂型電氣設(shè)備或充砂型電氣設(shè)備部件的外殼,應(yīng)至少符合GB4208規(guī)定的IP43防護(hù)等級(jí)。這些外殼應(yīng)標(biāo)記“X',符號(hào)。當(dāng)充砂型設(shè)備的外殼、充砂型設(shè)備部件的外殼或充砂型Ex元件的外殼規(guī)定安裝在符合GB3836.1的其他外殼內(nèi)時(shí),外部外殼防護(hù)等級(jí)至少應(yīng)為IP54。內(nèi)部外殼IP代碼不必說(shuō)明。外殼的最大間隙比實(shí)際填料的最小尺寸至少小0.1mm,并且不超過(guò)0.9mm以防止填料漏出。4.1.3峨充方法填充應(yīng)使填料內(nèi)不留空隙(例如通過(guò)搖勻法),充砂型設(shè)備、設(shè)備部件或Ex元件內(nèi)部自由空間應(yīng)全部充滿填料(同時(shí)見(jiàn)4.3.2),4.1.4封閉方法充砂型設(shè)備、充砂型設(shè)備部件或充砂型Ex元件的外殼應(yīng)由工廠封閉,不損壞外殼或封閉措施時(shí)不能打開(kāi)。填充口應(yīng)采用同樣方法封閉。
6GB3836.7-2004/IEC60079-5:1997注:合適的封裝技術(shù)如:焊接、硬焊、接合面粘接、鉚接、粘接螺紋。4.2墳充材料4.2.1文件由制造廠提供并由檢驗(yàn)單位按GB3836.1(見(jiàn)型式檢驗(yàn)文件)審查的文件應(yīng)準(zhǔn)確地說(shuō)明填充材料、填充過(guò)程及確保進(jìn)行正確填充的方法。說(shuō)明應(yīng)包括:—填充材料制造廠的名稱和地址;—確切、完整的填充材料鑒定書;—填充材料(顆粒)尺寸(見(jiàn)4.2.2).4.2.2要求顆粒大小應(yīng)在下列按ISO565規(guī)定的篩子限度范圍內(nèi):—上限:標(biāo)稱篩孔尺寸為1mm的金屬絲網(wǎng)或鉆孔金屬板;—下限:標(biāo)稱篩孔尺寸為0.5mm的金屬絲網(wǎng)。只允許用石英或玻璃顆粒。檢驗(yàn)單位不必對(duì)4.2.1和4.2.2的填料進(jìn)行檢驗(yàn)。4.2.3試驗(yàn)填充材料應(yīng)承受5.1及5.2規(guī)定的介電強(qiáng)度試驗(yàn)。4.3距離4.3.1除非在本部分中另有其他規(guī)定,設(shè)備導(dǎo)電部件與絕緣元件間、以及與外殼內(nèi)表面間通過(guò)填料的最短距離均應(yīng)符合表1規(guī)定,該規(guī)定不適用于穿過(guò)外殼壁的外部連接件用的導(dǎo)體。這種導(dǎo)體應(yīng)符合4.3.3的規(guī)定。表1填料內(nèi)的距離最高交流電壓有效值或直流電壓的最高值/v}最小距離/mm}U-<2755275
7GB3836.7-2004/IEC60079-5;19974.3.3不符合4.3.1和4,3.2的電氣裝置或兀件應(yīng)米用GB3836.1甲夕9舉的防爆型式之一。4.4材料的使用在4.3規(guī)定的范圍內(nèi),導(dǎo)電部件和外殼壁間使用的材料應(yīng)符合5.1.3然燒試驗(yàn)的規(guī)定(對(duì)外部布線的絕緣及填料除外)。4.5電纜引入裝置和絕緣套管充砂型電氣設(shè)備、充砂型設(shè)備部件或充砂型Ex元件外殼的電纜引人裝置和絕緣套管不應(yīng)破壞4.1.2規(guī)定的外殼防護(hù)等級(jí)。電氣設(shè)備的電纜引人裝置和絕緣套管應(yīng)按4.1.4的規(guī)定保護(hù)和密封起來(lái),對(duì)于充砂型外殼放人另一個(gè)符合4.1.2要求的外殼內(nèi)時(shí),GB3836.1規(guī)定的電纜及導(dǎo)管引人裝置要求不適用于引人充砂型外殼的電纜引人裝置和絕緣套管。4.6能f貯存裝里在充砂型電氣設(shè)備外殼內(nèi)、電氣設(shè)備部件內(nèi)或Ex元件中的所有電容的總貯存能量,在正常運(yùn)行時(shí)不應(yīng)超過(guò)20Je不允許使用可能損壞防爆型式的干電池和蓄電池。注:干電池和蓄電池的要求正在考慮之中。4.7溫度限制每個(gè)充砂型電氣設(shè)備、電氣設(shè)備部件或Ex元件應(yīng)對(duì)事故狀態(tài),如短路或熱過(guò)載進(jìn)行保護(hù),以保證外殼壁和外殼壁到填料內(nèi)5mm深處的溫度不超過(guò)相應(yīng)溫度組別的允許溫度。4.8故障條件在制造廠規(guī)定的任何相關(guān)產(chǎn)品標(biāo)準(zhǔn)中所述的過(guò)載及在下列情況下,如可能產(chǎn)生過(guò)壓或過(guò)流的任一單個(gè)內(nèi)部電氣故障時(shí),應(yīng)能保持其防爆型式“4":任何元件的短路;由于任何元件的故障產(chǎn)生的斷路;—印刷電路中的故障;—等等。如果一種故障能導(dǎo)致一個(gè)或多個(gè)隨后的故障,例如某元件的過(guò)載,可將原來(lái)的和隨后的一些故障認(rèn)為是單一故障。若無(wú)產(chǎn)品標(biāo)準(zhǔn),應(yīng)是制造廠規(guī)定的過(guò)載。當(dāng)考慮故障狀態(tài)和非故障時(shí),應(yīng)假定電壓U。就是施加于端子上的電壓。4.8.1不必考慮的故障以下故障不必考慮:a)電阻值低于額定值:—薄膜電阻;—繞線電阻及螺旋形單層線圈;當(dāng)其在不大于各元件制造廠規(guī)定的額定電壓和功率的2/3條件下使用時(shí)。b)短路情況:—塑料箔電容器;—陶瓷電容器;—紙電容器;當(dāng)其在不大于各元件制造廠規(guī)定的額定電壓的2/3條件下使用時(shí)。C)絕緣故障:—隔離不同電路的光電禍合器和繼電器;當(dāng)兩電路的最大電壓有效值的總和U不高于1000V,且兩不同電路間元件的額定電壓至少是U
8GB3836.7-2004/IEC60079-5:1997的1.5倍時(shí)。符合GB3836.3的變壓器、線圈和繞組或符合GB3836.4-2000中8.1的變壓器是不發(fā)生故障的。如果裸露導(dǎo)電部件或印刷電路間的爬電距離或電氣間隙至少等于表2中的值(測(cè)量爬電距離方法見(jiàn)GB3836.3和GB3836.4),則不必考慮短路的可能性。按照表2,部件間的最大峰值電壓應(yīng)當(dāng)考慮作為峰值電壓,如果部件在電氣上是隔離的,兩電路的最大峰值電壓的總和應(yīng)認(rèn)為是峰值電壓。最大峰值電壓的檢驗(yàn)應(yīng)考慮其正常工作條件(瞬態(tài)忽略不計(jì))和本標(biāo)準(zhǔn)中規(guī)定的故障情況。下列條件適用于符合表2規(guī)定的涂層下的爬電距離:—敷形涂層應(yīng)具有密封導(dǎo)體的作用以防止潮氣進(jìn)入;—應(yīng)粘附在導(dǎo)電部件及絕緣材料上;—若敷形涂層采用噴涂方法涂覆時(shí),那么,應(yīng)分別涂覆兩次;—僅要求一層涂層時(shí)可使用如浸涂、涂刷、真空浸漬方法,目的是要達(dá)到有效、持久、連續(xù)密封;—只要軟焊期間不會(huì)損害軟焊面層,則該面層作為兩涂層之一。從絕緣中伸出的導(dǎo)電部件(包括軟焊元件頭),除了用特殊方法使其獲得連續(xù)的有效密封之外,不應(yīng)視為有涂層。當(dāng)從涂層中顯露出裸露導(dǎo)體時(shí),表2的相比漏電起痕指數(shù)(CTI)適用于絕緣及敷形涂層。表2爬電距離和通過(guò)婉料的距離峰值電壓/V爬電距離/mmIRC最小值涂層下的爬電距離/mm通過(guò)填料的距離/mm101.50.61.53021000.71.56031001159041001.3219081752.63375101753.33550151755375018175651000251758.35130036175121015754917513.310超過(guò)1575V(峰值)的電壓通常認(rèn)為是易發(fā)生故障的。注:電壓10V(峰值)以下,絕緣材料的CTI不需作規(guī)定4.8.2限制溫度的保護(hù)裝里通過(guò)內(nèi)部或外部、電的或熱的保護(hù)裝置可以達(dá)到限制溫度的目的。該裝置不應(yīng)是自動(dòng)復(fù)位式的。當(dāng)使用熔斷器作為保護(hù)裝置時(shí),熔斷元件應(yīng)是封閉型的,例如在玻璃或陶瓷中。對(duì)于60V以上的電壓,熔斷器的通斷能力應(yīng)符合GB9364.1或GB13539.1的要求。4.8.3電源預(yù)期短路電流設(shè)計(jì)成連接不超過(guò)250V交流外部電源的充砂型電氣設(shè)備、電氣設(shè)備部件及Ex元件應(yīng)適合于1500A的預(yù)期短路電流,在標(biāo)志中規(guī)定了允許的預(yù)期短路電流值的除外。在一些裝置中可能出現(xiàn)高于1500A的預(yù)期電流,例如在高電壓時(shí)。若限流裝置必須將預(yù)期電流值限制到不高于熔斷器的額定斷開(kāi)值時(shí),按照4.8.1a)規(guī)定,該限流裝置應(yīng)是一個(gè)電阻器,其額定值應(yīng)為:—額定電流:1.5X1.7X熔斷器的I.;—使用的外部最大電壓Um;
9GB3836.7-2004/IEC60079-5:1997—額定功率:1.SX(1.7X熔斷器的I=)2X限流裝置電阻。5檢查和試驗(yàn)5.1型式檢查和試驗(yàn)5.1.1外殼壓力的型式試驗(yàn)無(wú)論外殼的容積如何,外殼都應(yīng)承受過(guò)壓0.05MPa的壓力型式試驗(yàn)。任何尺寸不應(yīng)出現(xiàn)超過(guò)0.5mm的永久變形,施加壓力歷時(shí)60s,公差范圍為+5%一。%。對(duì)于沒(méi)有呼吸和排氣口的充砂型外殼,如果內(nèi)有塑料箔、紙或陶瓷類型之外的電容器,且填充材料的體積小于8倍電容容積,則壓力型式試驗(yàn)過(guò)壓1.5MPa,歷時(shí)60s,公差范圍為+5%-0%,試驗(yàn)應(yīng)在設(shè)備的正常狀態(tài)下進(jìn)行,但是可以在外殼沒(méi)有填充材料下進(jìn)行。5.1.2外殼防護(hù)等級(jí)檢驗(yàn)外殼防護(hù)等級(jí)檢驗(yàn)方法應(yīng)按GB4208進(jìn)行。呼吸裝置應(yīng)安裝就位,該試驗(yàn)要在5.1.1的壓力試驗(yàn)后進(jìn)行。5.1.3材料的可嫌性應(yīng)符合GB3836.2的可燃性要求(見(jiàn)GB3836.2-2000附錄A.3.3).5.1.4繽充材料的電氣強(qiáng)度試驗(yàn)填充材料的絕緣性能應(yīng)在填充之前選取填充材料樣品進(jìn)行試驗(yàn),電極位置見(jiàn)圖1。電極應(yīng)被填充材料筱蓋,其厚度在任何方向均不小于10mm,樣品應(yīng)放在溫度23℃士2*C,相對(duì)濕度45%'-55%為條件下24h,然后將1000V,公差范圍為+5%-0%的直流試驗(yàn)電壓加在電極上。如果填充材料漏電電流不超過(guò)1。一‘A,則視為合格。如材料不合格不允許進(jìn)一步調(diào)節(jié)和重做試驗(yàn)。5.1.5最高溫度當(dāng)用熔斷器作為溫度限制保護(hù)裝置時(shí),應(yīng)在連續(xù)電流不超過(guò)1.7倍的額定電流下通過(guò)熔斷器電路,測(cè)量故障狀態(tài)下最高溫度。注:為了模擬可能引起高于正常運(yùn)行時(shí)溫度的故障狀態(tài),適合于采用裝在電氣設(shè)備內(nèi)的功率元件施加可能產(chǎn)生的最大功率應(yīng)選擇這類元件并裝在該設(shè)備中,以使它們能反映出所代表元件的熱特性。5.2出廠檢查和試驗(yàn)5.2.1外殼的出廠壓力試驗(yàn)外殼容積如大于100cm,時(shí),需進(jìn)行出廠壓力試驗(yàn)。過(guò)壓。.05MPa,歷時(shí)60s,公差范圍為+5%一。環(huán),任何尺寸不應(yīng)出現(xiàn)超過(guò)0.5mm的永久變形。試驗(yàn)應(yīng)在設(shè)備的正常狀態(tài)下進(jìn)行,但可以在外殼沒(méi)有填充材料下進(jìn)行。如果外殼通過(guò)了4倍于5.1.1中規(guī)定的參考?jí)毫?0.05MPa或1.5MPa)的型式試驗(yàn),出廠壓力試驗(yàn)可省略。5.2.2墳充材料的電氣強(qiáng)度試驗(yàn)填充材料的絕緣性能應(yīng)在填充之前,選取填充材料樣品進(jìn)行試驗(yàn)。電極裝置見(jiàn)圖1,電極的填充材料覆蓋厚度任何方向不小于10mm。在下列氣候條件下試驗(yàn)電壓為直流1000V,公差范圍為+5%一。%:—溫度23℃士2'C;—相對(duì)濕度45%-55%.如果泄漏電流不超過(guò)10-A,認(rèn)為該填充材料合格。如填充材料首次試驗(yàn)不合格,可烘干,并且再次試驗(yàn)。6標(biāo)志標(biāo)志應(yīng)符合GB3836.1的規(guī)定,并應(yīng)包括下述補(bǔ)充內(nèi)容。
10GB3836.7-2004/IEC60079-5:1997補(bǔ)充標(biāo)志:—“外殼由制造廠密封,不準(zhǔn)打開(kāi),’;—每個(gè)連接裝置(對(duì)外連接)應(yīng)清晰地標(biāo)出額定電壓及電流值(例如“24Vd.c.,200mA","230V,100mA");—與防爆型式關(guān)聯(lián)的外部熔斷器數(shù)據(jù),如“要求的外部熔斷器:315mA";—若按4.8.3設(shè)計(jì)不同于1500A短路電流的電氣設(shè)備,應(yīng)標(biāo)明外部電源允許的預(yù)期短路電流值,如“允許的電源短路電流:35A",尺寸單位為毫米電極(黃俐)尺寸公差為士1圖1填料的介電強(qiáng)度試驗(yàn)裝置