《監(jiān)理砂樁試樁總結(jié)報(bào)告》由會(huì)員上傳分享,免費(fèi)在線閱讀,更多相關(guān)內(nèi)容在應(yīng)用文檔-天天文庫(kù)。

1、晉江市東石鎮(zhèn)環(huán)灣大道工程試驗(yàn)段K0+060~K0+100試樁監(jiān)理總結(jié)報(bào)告編制審核福建泉宏工程管理有限公司二〇一四年十月目錄一、試樁概況··········································3二、試樁目的··········································3三、試樁時(shí)間··········································3四、技術(shù)標(biāo)準(zhǔn)及依據(jù)····································3五、施工前監(jiān)理準(zhǔn)備工作·······················

2、·········3六、施工中監(jiān)理控制····································4七、施工中安全控制····································6八、工程資料整理······································8九、試樁總結(jié)··········································9一、試樁概況本次選取K0+060~K0+100段進(jìn)行試樁試驗(yàn),全長(zhǎng)40m,共計(jì)18098m/1539根。K0+060-K0+080段實(shí)際施工358根樁,總長(zhǎng)為4561.25m;K0

3、+080-K0+100段實(shí)際施工639根樁,總長(zhǎng)為8153.1m;二、試樁目的選擇不同地貌、不同地層及不同工況的典型區(qū)域進(jìn)行試樁,以掌握對(duì)該場(chǎng)地的施工經(jīng)驗(yàn)和施工參數(shù)。通過(guò)成樁試驗(yàn),確定填砂量、提升速度、時(shí)間、電機(jī)工作電流等,作為控制質(zhì)量的標(biāo)準(zhǔn),驗(yàn)證設(shè)計(jì)參數(shù)的合理性。三、試樁時(shí)間施工于2014年9月18日下午16:00時(shí)開(kāi)始,于2014年10月4日結(jié)束,歷時(shí)17天。四、技術(shù)標(biāo)準(zhǔn)及依據(jù)1、陜西市政建筑設(shè)計(jì)研究院提供的設(shè)計(jì)圖紙;2、《公路路基設(shè)計(jì)規(guī)范》(JTGD30-2004);3、《公路軟土地基路堤設(shè)計(jì)與施工技術(shù)細(xì)則》(JTG/TD31-02-2013);4、《公路路基施工

4、技術(shù)規(guī)范》(JTGF10-2006);5、《公路工程質(zhì)量檢驗(yàn)評(píng)定標(biāo)準(zhǔn)》(第一冊(cè))(JTGF80/1-2004);五、施工前監(jiān)理準(zhǔn)備工作1、施工監(jiān)理準(zhǔn)備1)施工前對(duì)地面構(gòu)筑物、地下管線進(jìn)行調(diào)查、拆移,進(jìn)行場(chǎng)地清表、平整;挖設(shè)臨時(shí)排水溝,疏干地表水,使地基面層保持干燥狀態(tài)。2)布置砂石料存放場(chǎng),修建作業(yè)場(chǎng)內(nèi)滿足施工機(jī)械通行的施工便道。3)施工單位先行根據(jù)設(shè)計(jì)圖紙測(cè)量放樣路基中心線及軟基處理邊線并用石灰線醒目標(biāo)注,監(jiān)理單位進(jìn)行復(fù)核測(cè)量,路基填筑至標(biāo)高+0.8m。4)樁機(jī)進(jìn)場(chǎng)、組裝調(diào)試,繪制樁位平面圖。六、施工中監(jiān)理控制1、施工監(jiān)理控制要點(diǎn):1)施工前監(jiān)理單位須了解施工場(chǎng)地工程

5、地質(zhì)情況,并熟悉設(shè)計(jì)圖紙。2)施工單位根據(jù)砂樁施工布樁平面圖測(cè)量放樣出每根樁的樁位,監(jiān)理單位旁站并把誤差控制在5cm以內(nèi)。場(chǎng)地樁位放樣后,做好現(xiàn)場(chǎng)原始測(cè)量記錄,以便備查。3)施工時(shí)做好詳細(xì)的監(jiān)理原始旁站記錄,現(xiàn)場(chǎng)監(jiān)理進(jìn)行全程旁站和作好拍攝照片或錄像等實(shí)態(tài)記錄,為施工控制及質(zhì)量檢測(cè)提供可靠的參考依據(jù)。4)每根樁施工前必須檢查排樁軸線及樁距,無(wú)誤后才能施工。5)施工中如出現(xiàn)異常現(xiàn)象需做好現(xiàn)場(chǎng)旁站記錄,并及時(shí)匯報(bào)情況,請(qǐng)有關(guān)部門(mén)進(jìn)行處理解決。2、施工過(guò)程控制及方法:現(xiàn)場(chǎng)監(jiān)理旁站過(guò)程中,沉管速度均控制在2~3m/min,電機(jī)工作電流范圍為90A~180A(雙電機(jī)),砂樁終孔以進(jìn)

6、入持力層≥1m為標(biāo)準(zhǔn)控制。當(dāng)樁底進(jìn)入持力層時(shí)電機(jī)電流約90A左右;砂料的控制:采用滲水率較高的潔凈中粗砂,含泥量不應(yīng)大于3%,細(xì)度模數(shù)不小于3.0,有機(jī)質(zhì)含量不大于1%,滲透系數(shù)不小于5×10-3cm/s。樁徑的控制:用鋼尺測(cè)量樁徑;經(jīng)鋼尺測(cè)量成樁后的直徑為D500mm;樁距的控制:用鋼尺測(cè)量?jī)蓸吨g的間距;經(jīng)鋼尺測(cè)量?jī)蓸吨g的間距均為1.5m。垂直度控制:在樁管側(cè)面設(shè)一道鋼圈,并目測(cè)鋼圈中心的吊錘與鋼圈之間的偏差,用卷尺測(cè)量鋼圈與吊錘之間的距離來(lái)確定是否符合設(shè)計(jì)要求,垂直度基本控制在1.5%H以內(nèi)(H為樁長(zhǎng)),經(jīng)測(cè)量結(jié)果垂直度均小于設(shè)計(jì)值;灌砂量的控制:目測(cè)拔管完成后

7、有無(wú)灌滿樁體(樁頂面一下1m左右)設(shè)計(jì)要求單樁灌砂量不應(yīng)小于0.95*0.237*h(h為實(shí)際打樁樁長(zhǎng)),如發(fā)現(xiàn)未灌滿樁體,采用人工向孔內(nèi)投料同時(shí)向管內(nèi)充水,樁頭部位用振搗棒振搗密實(shí)至設(shè)計(jì)標(biāo)高,若低于設(shè)計(jì)的每m灌砂量時(shí),在旁邊補(bǔ)樁一根。單根砂樁灌砂量約為0.236m3/m,基本符合設(shè)計(jì)要求;在樁管上拔過(guò)程中,可用“鐵錘敲擊法”判斷有無(wú)“砂塞”。當(dāng)樁管發(fā)出清脆的當(dāng)當(dāng)金屬聲時(shí),說(shuō)明沒(méi)有“砂塞”,當(dāng)音質(zhì)沉悶時(shí),說(shuō)明管內(nèi)存在“砂塞”??刹捎谩胺床宸ā毕吧叭?。在出現(xiàn)砂量不足或“水樁頭”時(shí),均采用在補(bǔ)樁的同時(shí),用“反插法”予以解決。拔管速度的控

當(dāng)前文檔最多預(yù)覽五頁(yè),下載文檔查看全文

此文檔下載收益歸作者所有

當(dāng)前文檔最多預(yù)覽五頁(yè),下載文檔查看全文
溫馨提示:
1. 部分包含數(shù)學(xué)公式或PPT動(dòng)畫(huà)的文件,查看預(yù)覽時(shí)可能會(huì)顯示錯(cuò)亂或異常,文件下載后無(wú)此問(wèn)題,請(qǐng)放心下載。
2. 本文檔由用戶上傳,版權(quán)歸屬用戶,天天文庫(kù)負(fù)責(zé)整理代發(fā)布。如果您對(duì)本文檔版權(quán)有爭(zhēng)議請(qǐng)及時(shí)聯(lián)系客服。
3. 下載前請(qǐng)仔細(xì)閱讀文檔內(nèi)容,確認(rèn)文檔內(nèi)容符合您的需求后進(jìn)行下載,若出現(xiàn)內(nèi)容與標(biāo)題不符可向本站投訴處理。
4. 下載文檔時(shí)可能由于網(wǎng)絡(luò)波動(dòng)等原因無(wú)法下載或下載錯(cuò)誤,付費(fèi)完成后未能成功下載的用戶請(qǐng)聯(lián)系客服處理。