資源描述:
《9-27斷油穩(wěn)燃調(diào)試程序》由會(huì)員上傳分享,免費(fèi)在線閱讀,更多相關(guān)內(nèi)容在教育資源-天天文庫(kù)。
1、印度尼西亞龍灣3×315MW燃煤電廠工程PLTU3BANTEN(3×315MW)Project調(diào)試程序CommissioningProcedure印度尼西亞龍灣3×315MW燃煤電廠工程PLTU3BANTEN(3×315MW)Project調(diào)試程序CommissioningProcedure斷油穩(wěn)燃調(diào)試程序CommissioningProcedureofFuelOilCut-offandStableCombustionREV0SCCTI-TS-GL-CS-003-2009APage19of17PT.PLN(PERSERRO)Owner’sFileNo.0703-00-M-01-H-002PTR
2、EKADAYAELEKTRIKAPT.PLN(PERSERRO)JASASERTIFIKASI(LMK)CONSORTIUMOFDONGFANGELECTRICCORPORATIONANDDALLEENERGY四川電力調(diào)試所SiChuanElectricPowerCommissioning&TestInstitute印度尼西亞龍灣3×315MW燃煤電廠工程PLTU3BANTEN(3×315MW)Project批準(zhǔn)ApprovalWeiQiang日期Date斷油穩(wěn)燃調(diào)試程序CommissioningProcedureoffueloilcutandstablecombustiontestofboi
3、ler審核ReviewPuXiaoqin日期Date校核CheckZhangyu日期Date文件號(hào)FileNo.SCCTI-TS-GL-CS-003-2009A版本號(hào)REV0印度尼西亞龍灣3×315MW燃煤電廠工程PLTU3BANTEN(3×315MW)Project調(diào)試程序CommissioningProcedure斷油穩(wěn)燃調(diào)試程序CommissioningProcedureofFuelOilCut-offandStableCombustionREV0SCCTI-TS-GL-CS-003-2009APage19of17目錄TableofContents1.調(diào)試目的PURPOSE32.調(diào)試范圍
4、SCOPE33.編制依據(jù)PREPARATIONBASIS34.系統(tǒng)及設(shè)備簡(jiǎn)介BRIEFDESCRIPTIONOFSYSTEMANDEQUIPMENT35.調(diào)試所需工具、儀器TOOLSANDINSTRUMENTFORCOMMISSIONING76.調(diào)試應(yīng)具備的條件PREREQUISITEFORCOMMISSIONING77.調(diào)試程序COMMISSIONINGPROCEDURE98.安全措施SAFETYMEASURES119附錄APPENDIX139.1附錄1調(diào)試條件檢查確認(rèn)表Appendix1CommissioningConditionChecklist149.2附錄2試運(yùn)參數(shù)記錄表Append
5、ix2FTrialRunParametersRecord16印度尼西亞龍灣3×315MW燃煤電廠工程PLTU3BANTEN(3×315MW)Project調(diào)試程序CommissioningProcedure斷油穩(wěn)燃調(diào)試程序CommissioningProcedureofFuelOilCut-offandStableCombustionREV0SCCTI-TS-GL-CS-003-2009APage19of171.調(diào)試目的Purpose在鍋爐帶負(fù)荷啟動(dòng)調(diào)試過(guò)程中實(shí)現(xiàn)穩(wěn)燃、安全斷油,可節(jié)約燃油,提高機(jī)組運(yùn)行經(jīng)濟(jì)性。Stablecombustionandsafefueloilcut-offreach
6、edintheprocessofcommissioningforboilerstart-upwithloadcansavefueloilandincreaseeconomicoperationofunits.2.調(diào)試范圍Scope本程序適用于鍋爐斷油低負(fù)荷穩(wěn)燃調(diào)試,包括鍋爐主保護(hù)的檢查確認(rèn)、斷油前的燃燒調(diào)整、斷油試驗(yàn)、斷油后的燃燒調(diào)整。ThisProcedureisapplicabletothecommissioningoflowloadstablecombustionafterboilerfueloilcut-off,includingcheckandverificationofboiler
7、protection,combustionsettingbeforefueloilcut-off,fueloilcut-offtestandcombustionsettingafterfueloilcut-off.3.編制依據(jù)PreparationBasis3.1印度尼西亞龍灣3×315MW燃煤電廠機(jī)組整套啟動(dòng)試運(yùn)調(diào)試大綱StartupandcommissioningplansforPLTU3BA